AC3000 series interrow air cooled air conditioner(12KW~65KW)

AC3000 series interrow air-cooled air conditioner is a cooling, efficient, energy-saving precision air conditioner for the room, which is suitable for the micro-module data center with high temperature or humidity control precision and high sensible heat requirements. The inter-column air conditioner is placed in the rack arrangement and installed side by side with the server cabinet. The air is discharged from the front of the unit, and the air is returned at the rear. It is close to the heat source and cooled at the near end. It can meet the environmental control requirements of various equipment rooms in different regions. All air-cooled products are equipped with R410A refrigerant type DC inverter scroll compressor, which is highly efficient and energy saving.

consult

馬政發(fā)13911282237

  • Efficient and reliable

    Adopt permanent magnet synchronous DC brushless frequency conversion, low noise, small vibration scroll compressor, can automatically adjust the cooling capacity according to the dynamic load of the machine room 10%-100%; The unit is equipped with a standard gas-liquid separator to separate the liquid refrigerant before the compressor suction port to prevent the compressor “ Liquid hammer ” .

  • Energy efficient

    The unit adopts inverter scroll compressor, can choose the inverter compressor scheme; High performance EC centrifugal fan, large air volume, high static pressure, smooth operation, low noise; Fully enclosed electronic expansion valve control, accurate adjustment, to ensure the stability of refrigerant flow, reduce temperature fluctuations in the equipment room; The outdoor fan adopts stepless variable speed regulation technology to ensure stable operating pressure and reduce unit energy consumption.

  • Intelligent control

    Intelligent controller for PID operation, automatic adjustment of compressor and fan speed; The compressor speed can be automatically adjusted between 1800 and 7000RPM; The standard RS485 communication interface can realize coordination and linkage with external devices, and help the entire air conditioning system in the computer room intelligent and energy-saving control.

Application scenario

  • Computer Room
    Data centers with high heat density and low PUE value requirements, computer rooms

  • System Room
    Such as supercomputing center, data center, cloud computing center, communication room, switching room, transmission room, electronic information system room

  • Data Center
    Integrated Micromodule Data Center

  • Precision Environment
    Precision environments such as container data centers
The air conditioner in a small equipment room is suitable for places that have high requirements on ambient temperature and humidity. High heat density, low PUE value requirements for data centers, computer rooms.
Such as supercomputing center, data center, cloud computing center, communication room, switching room, transmission room, electronic information system room.  
Integrated micro-module data center, container data center and other precision environment.
    Technical specification

    Model AC3000-12 Series AC3000-25 Series AC3000-35 Series AC3000-40 Series AC3000-50 Series AC3000-65 Series
    Indoor return air condition: 37.8℃ DB/ 20%RH; Outdoor conditions (air cooling) : 35℃
    Cooling capacity (kw) 14.7 26.3 36.2 43.7 54.5 65.6
    Cooling capacity (kw) 14.7 26.3 36.2 43.7 54.5 65.6
    Indoor return air condition: 37℃ DB/ 24%RH; Outdoor conditions (air cooling) : 35℃
    Cooling capacity (kw) 14.5 26 35.8 43.1 53.3 65
    Cooling capacity (kw) 14.5 26 35.8 43.1 53.3 65
    Indoor return air condition: 35℃ DB/ 30%RH; Outdoor conditions (air cooling) : 35℃
    Cooling capacity (kw) 13.3 25.1 35.8 42 52.2 62.1
    Cooling capacity (kw) 13.3 25.1 35.8 42 52.2 62.1
    Function Optional constant temperature and humidity function
    Electric heating capacity (kw) 1 1 4 6 6 6
    Humidification capacity (kg/h) 1.5 1.5 1.5 3 3 3
    Humidification method Wet film humidification
    Indoor unit air volume (m³/h) 2700 5000 6000 8500 10500 12000
    Number of indoor fans 4 5 7 3 3 3
    Indoor unit power supply (V/PH/Hz) 3N+PE ~ 380V 50Hz
    Indoor unit size: Width * Depth * Height (mm) 300*1200*2000 300*1200*2000 300*1200*2000 600*1200*2000 600*1200*2000 600*1200*2000
    Indoor unit weight (kg) 255 300 250 350 380 400
    Outdoor unit weight (kg) 83 115 168 135 195 234
    主站蜘蛛池模板: 国产又爽又黄无码无遮挡在线观看 | 人妻少妇精品一区三区久久久久久 | らだ天堂√在线中文WWW | 久久久精品人妻无码专区不卡 | 亚洲精品无码久久久久久久 | 人人妻人人妻人人片AV | 精品人妻无码一区二区三区下一 | 久久精品成人欧美大片古装 | 日韩成视频在线精品 | 国产同事露脸对白在线视频 | AA片在线观看视频在线播放 | 中文字幕精品一区久久久久 | 男人一边吃奶一边做爰免费视频 | 澳门 日韩高清 一区二区 | BRAZZERSHD欧美大屁股 | 亚洲精品92内射 | 欧美日韩亚洲国产精品 | 精品乱伦一区二区 | 钙片gay男男gv在线观看 | 亚洲av狼在线 | 国内精品久久久久伊人av | 亚洲av福利无码无一区二区 | 后入到高潮免费观看 | 国产精品久久久久9999爆乳 | 国产精品自产拍高潮在线观看 | 又爽又黄又无遮挡的视频 | 亚洲午夜福利在线视频 | 熟妇丰满多毛的大隂户 | 国产乡下三级全黄三级bd | 玩两个丰满老熟女在线视频 | 777米奇69精品一区二区 国产精品白浆一区二小说 双乳被一左一右吃着动态图 | 亚洲中文无码成人影院 | 无码人妻av一二区二区三区 | 亚洲人成久久婷婷精品五码 | 久久精品性一区区裸体艺术 | 国产吃瓜黑料一区二区 | 精品免费久久久久久久 | 婷婷成人AV天堂草莓 | 99久久久精品免费观看国产 | 无码人妻品一区二区三区精99 | 狠狠色婷婷久久一区二区三区 |